• Natural Gas Engine Generator,Biomass Engine Generator, Biogas Engine Generator, Marine Diesel Generator
  • Diesel Generator| Marine Engine Genset| Gas Generator| Syngas Engines|
  • Home|Sitemap|Add to My FavoriteEnglish中文
HomeAbout Ettes PowerProductsCertificatesProjects ShowingFAQsDownloadContact Us
Home >> Products Center >> Methane-Gas-Generator
Key-Products
  • CNPC Gas Generators
  • MAN Gas Generator & CHP
  • Deutz Gas Generator & CHP
  • Cummins Gas Generators
  • Gas Generator & CHP
  • Syngas-Biomass Engines
  • Deutz Gas Genset
Methane-Gas-Generator
  • Natural Gas Generator
  • Biogas Generator
  • Oilfield Gas Generator
  • Landfill Gas Generator
  • Sewage Gas Generator
  • Shale Gas Generator
  • Coal Mine Gas Generator
  • CHP Gas Power Plant
Land-Diesel-Generator
  • Cummins Diesel Generator
  • Cummins Engines Datum
  • MTU Diesel Generator
  • Diesel Generator
Marine-Diesel-Generator
  • Cummins Marine Generator
  • Marine Generator
  • Marine Engines Datum
Syngas-Biomass-Generator
  • 300kW Biomass Engine
  • 500kW Biomass Engine
  • 1000kW Biomass Engine
  • Coalgas-Coking Gas Engine
Contact Us


Overseas Market Sales Dept.
Add:
No 188, Anshan West Road,
Nankai District, Tianjin, China
General Line: +86-22-23796980
Sales Line 01:+86-13672013688
Sales Line 02:+86-13821332565
FAX: +86-22-23796811
Email: sales@ettespower.com
           ettespower@gmail.com
Web Site: www.ettesgenerator.com
Skype No 1: ettespower
Skype No 2: ettes-power

        

Products Center

Sewage Gas Generator

Sewage Gas Generator
Sewage Gas Generator-1 Sewage Gas Generator-2 Sewage Gas Generator-3
► Sewage Gas Biogas and Sewage Sludge
 
The purification of wastewater produces leftovers: sewage sludge and sewage gas, valuable residues of wastewater treatment and also raw materials that can be used in energy generation/power generator.
 
Using sewage gas to reduce our own energy costs. Large quantities of energy-rich sewage gas are produced in the digester tanks of sewage treatment plants during the final step of wastewater treatment. This gas can be used as fuel for engine cogeneration units, which produce both electricity and heat simultaneously.
 
Sewage gas as an innovative raw material. After processing to produce gas of natural gas quality or hydrogen, sewage gas can be used for many purposes, such as fuelling vehicles, heating buildings and supplying them with power.
  
Sewage sludge as an energy source and raw material. Besides sewage gas, sewage sludge is also an important raw material. It can either be incinerated to generate electricity or be used in agriculture and landscaping. Because it contains valuable trace elements, such as phosphorus, sludge is suitable for use as a fertilizer. Some sewage sludge is used on agricultural land, subject to strict legal conditions, and small quantities are used in landscaping.

► Flow Chart of Sewage Gas Power Generation/CHP Plant



 
► Ettes Power Sewage Biogas Engine Generators 

Ettes Power is one of biggest manufactures and suppliers for gas engine generation/Power plant in China. Our generators enjoy hot markets more than 70 countries all over the world. Ettes Power Biogas engine Generation can be driven by world famous gas engines of Perkins, MWM-Deutz, SDEC 135, CNPC 190 and Low Speed 300 series, coupled with Stamford, Leroy Somer, Siemens or Marathon alternators, power ranging from 20kva upto 4000kva. 
 
CNPC 190 Sewage Digester Gas Generation from 200kw upto 1200kw     MAN Sewage Biogas Generation from 66kw upto 560kw
LOVOL Waste Water Gas Generator from 300kw upto 1000kw                 DEUTZ Sewage Gas Genset from 50kw upto 1200kw
 
Ettes Power gas power generators enjoy hot ready markets in domestic markets and overseas markets including South Africa, South America, Europe, Middle East and Southeast Asia countries etc. By adopting gas generators concerning technologies of Mixer, Ignitions System, Governor System from WOODWARD, HEINZMANN, ALTRONIC, IMPCO and equivalents, our gas generator set can run at highly steady & credible performance, easy for maintenance, much longer life-span and very economic in price based on wonderful quality.
Main Machine Configuraiton and Key Parts of Ettes Power Sewage Biogas Engine Genset
Gas Engine CNPC 190, Cummins, Perkins, MAN, MWM-DEUTZ, Low Speed 300 Series
Alternator Siemens, Leroy Somer, Stamford, Marathon
Governor/Actuator USA Woodward, Germany Motortech, Germany Heinzmann
Ignition Controller Altronic, Motortech, AFS
Spark Plugs Bosh, NGK, Motortech, STITT
Mixer USA Impco, Woodward or Heinzmann
Turbocharger ABB or Equal
Intercooler Germany GEC
Control Module: Deepea DSE7320/8610/8620, ComAp AMF25/IG-NT or Smartgen 6120/9510
Optional Device:
 
CHP/Cogeneration/CCHPTrigeneration
Steel Soundproof Container (sound attenuated canopy)
ATS and Synchronization Parallelling Panel
Remote Control
Power Station Central Management System
PMG Alternator
Cooling Tower, Remote Table Radiator
Oil and Water Heater
Muffler and Pipes
High Voltage Alternator 6.3kv and 10.5kv, High Voltage Electrical Control Cells (PT Cabinet, CT Cabinet, High Voltage outgoing cabinet, DC Panel, Groud Resistance Cabinet and low voltage distribution cabinet etc)
 



► Ettes Power Biogas Quality Requirements

• The content of CH4 ≥40%
• changing rate ≤2%/min
• Gas Temperature ≤40℃
• Pressure of biogas: 7-20kpa, rate of pressure change ≤1kpa/min
• H2S≤200mg/Nm3
• NH3≤20mg/Nm3
• Moisture Content≤40g/Nm3
• Impurity particular≤5um, Impurity content ≤30mg/Nm3

          
  
CNPC Sewage Biogas Engines & Generator Set (from 250kW upto 1000kW)
 

CNPC Series Sewage Biogas Engine Generator (50/60Hz)

Model
Rated
Power
Engine 
Model
Rotation 
Speed
No.of
Cylinders
& Type
 
Displace
ment (L)
Alternator
Overall
dimension
(L*W*H)(mm)
Weight
(kg)
Click for
Detail Data
kW
kVa
190 & 300
Series
RPM
(50HZ/60HZ)
Siemens
Marathon
or Equal
EJ-250NB
250
313
6190ZLT
1000/1200
6.L
35.7
1FC6 Series
4950*1760*2200
8750
click download pdf
EJ-320NB
320
400
G8V190ZLD
1000/1200
8.Vee
47.6
1FC6 Series
4566*2040*2200
10700
click download pdf
•EJ-400NB 400 500 12V190DT
1000/1200
12.Vee
71.5
1FC6 Series
4566*2040*2200
11500 click download pdf
EJ-450NB 450 563 12V190ZDT 1000/1200
12.Vee
71.5
1FC6 Series
4790*2040*2212
11800 click download pdf
EJ-500B 500 625 G12V190ZLDT
1000/1200
12.Vee
71.5
1FC6 Series
5260*2040*2500
12800
click download pdf
•EZ-500NB 500 625   6300D/T 600/600 6.L  161
1FC6 Series
6400*1600*2900 22000 click download pdf
EJ-600NB
600
750
G12V190ZLDT
1000/1200
 12.Vee
71.5
1FC6 Series
5260*2040*2500
12600
click download pdf
•EZ-600NB 600 750   8300D/T-1 500/500  8.L 215
1FC6 Series
6400*1600*2900 22000 click download pdf
•EZ-700NB 700 875   8300D/T-2 600/600 8.L 215
1FC6 Series
6400*1600*2900 22000 click download pdf
EJ-800NB
800
1000
H16V190ZLT
1000/1200
16.Vee
97.53
1FC6 Series
6070*2380*2776
22000
click download pdf
EJ-1000NB
1000
1250
H16V190ZLT
1000/1200
16.Vee
97.53
1FC6 Series
6070*2380*2776
22000
click download pdf
EZ-1000NB 1000 1250   8300ZLD/T-1 600/600 8.L 215
1FC6 Series 
6400*1600*3100 25000 click download pdf

Remarks:
• Model with "B" means for biogas; Model with "NB" means for both natural gas and biogas;
• Model with "•" means engine air intake is naturally aspirated (without turbocharger and intercooler), which is suitable for low quality methane gas.
• 50Hz & 60Hz are available, Various low Voltage and High Voltage of 3.3kV~13.8kV are available for options.
• Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel Control panels and CHP are available for options.
• The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.





Deutz Sewage Biogas Engines & Generator
(from 50KW upto 250KW).
 

Deutz Sewage Biogas Engines made in China (50/60Hz)

Model
Rated
Power
Engine 
Model
Bore*Stroke
(mm)
Displace
ment
(L)
No.of
Cylinders
& Type
Air Intake
Method
Overall 
dimension 
(L*W*H)(mm)
Weight
(kg)
Click for 
Detail Data
KW
KVA
ED-50NB 50 63 TBD226B 105*130 6.8
6.L
Natural 2320*980*1450 1050 click download pdf
ED-60NB 60 75 TBD226B 105*130 6.8
6.L
Natural 2320*980*1450 1100 click download pdf
EST-80NB 80 100 WD615 126*130 9.8
6.L
Natural 2700*980*1680 1900 click download pdf
ED-80NB
80
100
TBD226B
105*130
6.8
6.L
Turbo
2550*1100*1450
1250
click download pdf
EST-100NB
100
125
WD615
126*130
11.6
6.L
Natural
2750*1080*1680
2100
click download pdf
ED-100NB
100
125 BF6M1015 132*145 11.9
6.Vee
Natural
2350*1200*1750
1650
click download pdf
EST-120NB 120 150 WD615
126*130
9.8 6.L Turbo 2850*1100*1680 2250 click download pdf
ED-120NB
120
150
BF6M1015
132*145
11.9
6.Vee
Natural
2450*1200*1750
1780
click download pdf
EST-150NB
150
188
WD618
126*155
11.6
6.L
Turbo
3050*1100*1800
2210
click download pdf
ED-150NB
150 188
BF6M1015
132*145
11.9
6.Vee
Turbo
2600*1250*1750 2150 click download pdf
 EST-200NB 200 250 WD618 126*155 11.6 6.L Turbo 3050*1100*1800 2320 click download pdf
 ED-200NB 200 250 BF6M1015 132*145 11.9 6.Vee Turbo 2650*1460*1880 2250 click download pdf
 ED-250NB 250 313 BF8M1015 132*145 15.9 8.Vee Turbo 3000*1550*1950 2650 click download pdf
★Remarks:
• Low voltage of 380V/400V/415V/440V/480V/690V, High Voltage of 6.3KV/10.5KV and other special voltages are available.
• Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel panels and CHP are available for your options.
• Above power ratings are based on natural gas (PNG, LNG, CNG). For other gas types such as biogas, oilfield associated Gas and Coalmine Gas etc., the engine power rating will be adjusted according to the exact gas quality.
• The data herein can vary depending on individual production requirements or due to improved technology.
 





MAN Sewage Biogas Engines & Genset & CHP (from 66KW upto 560KW). 

 MAN Biogas/Landfill Gas/Sewage Gas Generators (50Hz, 1500rpm)

 Model
COP
Engine
Model
Engine
Power
Alternator
Configura
tion
Elec. Eff.
Heat Eff.
Tot. Eff.
Overall
dimension
(L*W*H)(mm)
Weight
(kg)
Click for
Detail Data
KW
MAN
KW
Leroy Somer 
or Equal
EM-66B5
66 E0834LE302
68
LSA Series
L4 38.3% 52.0% 90.2% 
2800*1050*1550
1800
click download pdf
EM-100B5 100 E0836LE202 110
LSA Series
L6 36.5% 49.3% 85.8% 3700*1150*1750 2200 click download pdf
EM-200B5 200 E2876LE202 220 LSA Series L6 36.7% 46.8% 83.5%  4300*1300*2000 4400 click download pdf
EM-220B5 220 E2676LE212 252 LSA Series L6 40.2% 49.1% 89.3% 4300*1300*2000 4600 click download pdf
EM-250B5 250 E2848LE322  265 LSA Series V8 38.1% 49.6% 87.7% 4300*1300*2000 4600 click download pdf
EM-350B5 350 E3268LE222 370 LSA Series V8 39.3% 50.5% 89.8% 5200*2000*2100 6600 click download pdf
EM-400B5 400 E2842LE202 420 LSA Series V12 38.1% 50.3% 88.4% 5200*2000*2100 6400 click download pdf
EM-450B5 450 E3262LE232 500 LSA Series V12 40.1% 48.9% 89.0% 5500*2000*2100 7500 click download pdf
EM-520B5 520 E3262LE202 550 LSA Series V12 38.3% 48.2% 86.5% 5200*2000*2100 7500 click download pdf

 MAN Biogas/Landfill Gas/Sewage Gas Generators (60Hz, 1800rpm)

 Model
COP
Engine
Model
Engine
Power
Alternator
Configura
tion
Elec. Eff.
Heat Eff.
 
Tot. Eff.
 
Overall
dimension
(L*W*H)(mm)
Weight
(kg)
Click for
Detail Data
KW
MAN
KW
Leroy Somer 
or Equal
EM-66B6
66 E0834LE302
68
LSA Series
L4 37.2% 52.5% 89.6%
2800*1050*1550
1800
click download pdf
EM-100B6 100 E0836LE202 110
LSA Series
L6 35.1% 53.7% 88.8% 3700*1150*1750 2200 click download pdf
EM-180B6 180 E2876LE302 200 LSA Series L6 34.6% 50.8% 85.4% 4300*1300*2000 4400 click download pdf
EM-220B6 220 E2676LE212 250 LSA Series L6 40.3% 46.4% 86.7% 4300*1300*2000 4600 click download pdf
EM-250B6 250 E2848LE322  295 LSA Series V8 35.7% 51.3% 87.0% 4300*1300*2000 4600 click download pdf
EM-390B6 390 E3268LE222  420 LSA Series V8 37.5% 50.5% 88.0% 5200*2000*2100 6600 click download pdf
EM-420B6 420 E2842LE322 462 LSA Series V12 38.4% 52.3% 90.7% 5500*2000*2100 7500 click download pdf
EM-560B6 560 E3262LE202 580 LSA Series V12 37.4% 51.5% 88.9% 3300*1700*1600 3300 click download pdf
★Remarks:
• Above Gensets Models are based on AC Voltage of 400/230V and 480V/270V, Other special low Voltages.
• Above data is based on gas HV 20.4MJ/ Nm³; Power Factor Cosφ=1; Exhaust Temperature decreased to 120℃; Heat Value Tolerance 8%, Output Power Tolerance 5%. 
• NOx Emissions Level <500mg/m3 . Special requirements for emissions data such as EPA Standard can be realized by adding SCR and CO Catalyst. 
• Engine Overhaul Time is around 50000~60000 hours.
• Wrranty terms: 15 Months after delivery , 12 Months after Installment or 8000 hours accumulated running time, which is subject to the earlier one.
• The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.





MWW Sewage Biogas Engines & Generators & CCHP ( from 400kw upto 3770KW).
 

MWW Sewage Biogas Engines made in Germany (50Hz)

  Model  
COP
(KW)
Engine
Model
Bore*Stroke
(mm)
Displace
ment
(L)
Ratation
Speed
(rpm)
Elec. 
Eff.
(%)
Therm. 
Eff.
(%)
Total 
Eff.
(%)
Overall 
dimension 
(L*W*H)(mm)
Weight
(kg)
Click for 
Detail Data
EMW-400B5
400 TCG2016V08C /
CG132-8
132*160
17.5
1500 42.8
42.1
84.9
3090*1490*2190
5340
click download pdf
EMW-600B5 600 TCG2016V12C /
CG132-12
132*160
26.3
1500 42.7 42.3 85.0
3690*1490*2190
7000
click download pdf
EMW-800B5 800 TCG2016V16C /
CG132-16
132*160
35
1500 42.8 42.3 85.1
4090*1590*2190
8450
click download pdf
EMW-1200B5 1200 TCG2020V12 /
CG170-12
170*195 53.1 1500 42.0 43.8 85.8 4790*1810*2210 11700 click download pdf
EMW-1560B5 1560  TCG2020V16 /
CG170-16
170*195 70.8 1500 41.7 44.0 85.7 5430*1810*2210 13320 click download pdf
EMW-2000B5 2000 TCG2020V20 /
CG170-20
170*195 88.5 1500 42.9 43.3 86.2 6200*1710*2190 17900 click download pdf
EMW-3770B5 3770 TCG2032V16 /
CG260-16
260*320 271.8 1000 43.0 39.9 82.9 9200*2690*3390 51200 click download pdf

MWM Sewage Biogas Engines made in Germany (60Hz)

  Model  
COP
(KW)
Engine
Model
Bore*Stroke
(mm)
Displace
ment
(L)
Ratation
Speed
(rpm)
Elec. 
Eff.
(%)
Therm. E
ff.
(%)
Total 
Eff.
(%)
Overall 
dimension 
(L*W*H)(mm)
Weight
(kg)
Click for 
Detail Data
EMW-400B6
400 TCG2016V08C /
CG132-8
132*160
17.5
1800 41.6
43.2
84.8
3170*1490*2190
5120
click download pdf
EMW-600B6 600 TCG2016V12C /
CG132-12
132*160
26.3
1800 41.4 43.7 85.1
3770*1490*2190
6260
click download pdf
EMW-800B6 800 TCG2016V16C /
CG132-16
132*160
35
1800 41.7 43.3 85.0
4130*1490*2190
6780
click download pdf
EMW-1200B6 1200 TCG2020V12 /
CG170-12
170*195 53.1 1500 41.8 43.8 85.6 5970*1790*2210 12850 click download pdf
EMW-1560B6 1560  TCG2020V16 /
CG170-16
170*195 70.8 1500 41.4 43.9 85.3 6640*1790*2210 14850 click download pdf
EMW-2000B6 2000 TCG2020V20 /
CG170-20
170*195 88.5 1500 42.6 43.3 85.9 7470*1710*2190 19400 click download pdf
EMW-3510B6 3510 TCG2032V16 /
CG260-16
260*320 271.8 900 43.3 38.5 81.8 9420*2690*3390 53300 click download pdf
★Remarks:
• Transport dimensions for gensets; components set up separately must be taken into consideration.
• According to ISO 3046/1 at U=0.4 kV,cos=1.0 for 50 Hz and methane number of MN-70 (MN-80 for some engine models) for natural gas.
• Exhaust gas cooled to 120°C for natural gas and 150°C (TCG2032 180°C) for biogas.
• NO ≤ 500 mg/Nm³; exhaust gas dry at 5 % O2.
• Data for special gas and dual gas operation on request.
 

► Typical Projects of ETTES Gas Engine Power Plant
  














































Inquire Sewage Gas Generator
Home|About Ettes Power|Products|Certificates|Projects Showing|FAQs|Download|Contact Us|Warranty Policy
Diesel Engine Generator, Diesel Engine Genset, Natural Gas Generator, Biogas Generator Set, Silent Soundproof Generator, Marine Engine Generator, Marine Diesel Generator, Diesel Power Generators
Biomass Syngas Engines, Landfill Gas Generator, Coal Bed Gas Coal Mine Gas Generator, Oilfield Gas Generator,Gas Engine Generator, Methane Gas Generator, Gas CHP Cogeneration, Gas Power Plant 
                

Copyright © 2006 Ettes Power Machinery Co.,LTD.All Rights Reserved.
www.ettespower.com Sitemap www.ettespower.com Sitemap