Coalbed methane (CBM/Coal Bed Methane/Coalmine Methane/Marsh Gas), is a form of natural gas extracted from coal beds/coal mines. In recent decades it has become an important source of energy in United States, Canada, and other countries. Australia has rich deposits where it is known as coal seam gas.
The term refers to methane adsorbed into the solid matrix of the coal. It is called 'sweet gas' because of its lack of hydrogen sulfide. The presence of this gas is well known from its occurrence in underground coal mining, where it presents a serious safety risk. Coalbed methane, often referred to as CBM, is distinct from a typical sandstone or other conventional gas reservoir, as the methane is stored within the coal by a process called adsorption. The methane is in a near-liquid state, lining the inside of pores within the coal (called the matrix). The open fractures in the coal (called the cleats) can also contain free gas or can be saturated with water.
Unlike much natural gas from conventional reservoirs, coalbed methane contains very little heavier hydrocarbons such as propane or butane, and no natural gas condensate. It often contains up to a few percent carbon dioxide. Some coal seams, such as those in certain areas of the Illawarra Coal Measures in NSW, Australia, contain little methane, with the predominant coal seam gas being carbon dioxide.
► Reference Diagram of Ettes Power Coalmine Methane/Coal Bed Methane Generation
The term refers to methane adsorbed into the solid matrix of the coal. It is called 'sweet gas' because of its lack of hydrogen sulfide. The presence of this gas is well known from its occurrence in underground coal mining, where it presents a serious safety risk. Coalbed methane, often referred to as CBM, is distinct from a typical sandstone or other conventional gas reservoir, as the methane is stored within the coal by a process called adsorption. The methane is in a near-liquid state, lining the inside of pores within the coal (called the matrix). The open fractures in the coal (called the cleats) can also contain free gas or can be saturated with water.
Unlike much natural gas from conventional reservoirs, coalbed methane contains very little heavier hydrocarbons such as propane or butane, and no natural gas condensate. It often contains up to a few percent carbon dioxide. Some coal seams, such as those in certain areas of the Illawarra Coal Measures in NSW, Australia, contain little methane, with the predominant coal seam gas being carbon dioxide.
► Reference Diagram of Ettes Power Coalmine Methane/Coal Bed Methane Generation
► Ettes Power Coalmine Gas/Coalbed Methane /Natural Gas Engine Power Generator
CNPC Coalmine Gas Engines & Generator Set (from 250KW upto 1500KW)
Remarks:
Deutz Coalmine Gas Engines & Generator (from 50KW upto 1200KW)
MAN Coalmine Gas Engines & Genset & CHP (from 50KW upto 560KW)
★Remarks:
• Above Gensets Models are based on 50HZ/1500RPM and 60HZ/1800RPM.
• Above Gensets Models are based on AC Voltage of 400/230V and 480V/240V, Other special low AC Voltage and High Voltage of 6.3KV-13.8KV are available for your options.
• Engine Model with “·” means driven by Perkins engines.
• Above data is based on gas heat value 36MJ/ Nm³; Power Factor Cosφ=1; Exhaust Temperature decreased to 120℃; Heat Value Tolerance 8%, Output Power Tolerance 5%.
• NOX Emissions Level <500mg/m3 . Special requirements for emissions data such as EPA Standard can be realized by adding SCR and CO Catalyst.
• Engine Overhaul Time is around 50000~60000 hours.
• MAN Engines warranty terms: 15 Months after delivery , 12 Months after Installment or 8000 hours accumulated running time, which is subject to the earlier one.
• The data herein can vary depending on individual production requirements or due to improved technology.
MWW Coalmine Gas Engines & Generators & CCHP (from 400KW upto 4500KW)
★Remarks:
Ettes Power is one of biggest manufactures and suppliers for gas engine generation/Power plant in China. Our generators enjoy hot markets more than 70 countries all over the world. Ettes Power Biogas engine Generation can be driven by world famous gas engines of Cummins, Perkins, MWM-Deutz, SDEC 135, CNPC 190 and Low Speed 300 series, coupled with Stamford, Leroy Somer, Siemens or Marathon alternators, power ranging from 20kva upto 4000kva.
CNPC 190 Shale Gas Generation from 300kw upto 1000kw MAN Shale Gas Generation from 66kw upto 560kw
Cummins Shale Gas enerator from 20kw upto 2000kw LOVOL Shale Gas Generator from 300kw upto 1000kw
Cummins Shale Gas enerator from 20kw upto 2000kw LOVOL Shale Gas Generator from 300kw upto 1000kw
Our gas power generators enjoy hot ready markets in domestic markets and overseas markets including South Africa, South America, Europe, Middle East and Southeast Asia countries etc. By adopting gas generators concerning technologies of Mixer, Ignitions System, Governor System from WOODWARD, HEINZMANN, ALTRONIC, IMPCO and equivalents, our gas generator set can run at highly steady & credible performance, easy for maintenance, much longer life-span and very economic in price based on wonderful quality.
► Ettes Power Shale Natural Gas to Energy Diagram
► Normal Requirements for natural gas/Shale Gas Quality
► Ettes Power Shale Natural Gas to Energy Diagram
Main Machine Configuraiton and Key Parts of Ettes Power Coalmine Methane Engine Generator | |
Gas Engine | CNPC 190, Cummins, Perkins, MAN, MWM-DEUTZ, Low Speed 300 Series |
Alternator | Siemens, Leroy Somer, Stamford, Marathon |
Governor/Actuator | USA Woodward, Germany Motortech, Germany Heinzmann |
Ignition Controller | Altronic, Motortech, AFS |
Spark Plugs | Bosh, NGK, Motortech, STITT |
Mixer | USA Impco, Woodward or Heinzmann |
Turbocharger | ABB or Equal |
Intercooler | Germany GEC |
Control Module: | Deepea DSE7320/8610/8620, ComAp AMF25/IG-NT or Smartgen 6120/9510 |
Optional Device: |
CHP/Cogeneration/CCHPTrigeneration Steel Soundproof Container (sound attenuated canopy) ATS and Synchronization Parallelling Panel Remote Control Power Station Central Management System PMG Alternator Cooling Tower, Remote Table Radiator Oil and Water Heater Muffler and Pipes High Voltage Alternator 6.3kv and 10.5kv, High Voltage Electrical Control Cells (PT Cabinet, CT Cabinet, High Voltage outgoing cabinet, DC Panel, Groud Resistance Cabinet and low voltage distribution cabinet etc) |
► Normal Requirements for natural gas/Shale Gas Quality
Normally speaking, Ettes Power require your gas can reach below standards:
• The content of CH4 ≥70%
• Gas Pressure: 2~8kpa for Cummins engines, 100~400kpa for JDEC Engines, rate of pressure change ≤1kpa/min
• H2S≤20mg/Nm3
• Total Sulfur Content 460mg/Nm3
• Dust Content ≤10mg/Nm3
• No Liquid Water, Moisture Content≤40g/Nm3
• Impurity particular≤5um, Impurity content ≤30mg/Nm3
• The content of CH4 ≥70%
• Gas Pressure: 2~8kpa for Cummins engines, 100~400kpa for JDEC Engines, rate of pressure change ≤1kpa/min
• H2S≤20mg/Nm3
• Total Sulfur Content 460mg/Nm3
• Dust Content ≤10mg/Nm3
• No Liquid Water, Moisture Content≤40g/Nm3
• Impurity particular≤5um, Impurity content ≤30mg/Nm3
CNPC Coalmine Gas Engines & Generator Set (from 250KW upto 1500KW)
• Model with "N" means for natural gas; Model with "B" means for biogas; Model with "NB" means for both natural gas and biogas;
• Model with "*" means engine is with compression 8:1 (suitable for low quality gas)
• Model with "•" means engine air intake is naturally aspirated (without turbocharger and intercooler), which is suitable for low quality methane gas.
• 50Hz & 60Hz are available, Various low Voltage and High Voltage of 3.3kV~13.8kV are available for options.
• Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel Control panels and CHP are available for options.
• The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.
• Model with "*" means engine is with compression 8:1 (suitable for low quality gas)
• Model with "•" means engine air intake is naturally aspirated (without turbocharger and intercooler), which is suitable for low quality methane gas.
• 50Hz & 60Hz are available, Various low Voltage and High Voltage of 3.3kV~13.8kV are available for options.
• Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel Control panels and CHP are available for options.
• The data herein is just for purpose of reference only and not binding. The data given in the official offer is decisive.
Deutz Coalmine Gas Engines & Generator (from 50KW upto 1200KW)
★Remarks:
• Low voltage of 380V/400V/415V/440V/480V/690V, High Voltage of 6.3KV/10.5KV and other special voltages are available.
• Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel panels and CHP are available for your options.
• Above power ratings are based on natural gas (PNG, LNG, CNG). For other gas types such as biogas, oilfield associated Gas and Coalmine Gas etc., the engine power rating will be adjusted according to the exact gas quality.
• The data herein can vary depending on individual production requirements or due to improved technology.
• Low voltage of 380V/400V/415V/440V/480V/690V, High Voltage of 6.3KV/10.5KV and other special voltages are available.
• Special requirements for Soundproof Canopy/Container, ATS, Synchronizing Parallel panels and CHP are available for your options.
• Above power ratings are based on natural gas (PNG, LNG, CNG). For other gas types such as biogas, oilfield associated Gas and Coalmine Gas etc., the engine power rating will be adjusted according to the exact gas quality.
• The data herein can vary depending on individual production requirements or due to improved technology.
MAN Coalmine Gas Engines & Genset & CHP (from 50KW upto 560KW)
MAN Coal Mine Gas Generator Set (50Hz, 1500rpm) |
|||||||||||||
Model
|
COP
|
Engine
Model |
Engine
Power |
Alternator
|
Configura
tion |
Elec. Eff.
|
Heat Eff.
|
Tot. Eff
|
Overall
dimension (L*W*H)(mm) |
Weight
(kg) |
Click for
Detail Data |
||
KW
|
MAN
|
KW
|
Leroy Somer
or Equal |
||||||||||
EM-50N5 | 50 | E0834E302 | 54 |
LSA Series
|
L4 | 36.5% | 53.5% | 90% |
2800*1050*1550
|
1600
|
|||
EM-66N5 | 66 | TBA | 72 |
LSA Series
|
L4 | 38.4% | 53.1% | 91.5% |
2800*1050*1550
|
1900
|
|||
EM-75N5 | 75 | TBA | 80 |
LSA Series
|
L4 | 36.8% | 52.2% | 90% | 3250*1100*1650 | 2000 | |||
EM-100N5 | 100 | E0836LE302 | 110 |
LSA Series
|
L6 | 36.8% | 49.6% | 86.4% | 3700*1150*1750 | 2200 | |||
EM-150N5 | 150 | E2876E312 | 150 |
LSA Series
|
L6 | 38.83% | 52.8% | 91.1% | 4000*1225*1875 | 3300 | |||
EM-200N5 | 200 | E2876LE302 | 210 | LSA Series | L6 | 37.2% | 48.9% | 86.1% | 4300*1300*2000 | 4400 | |||
EM-220N5 | 220 | E2676LE202 | 220 | LSA Series | L6 | 43.4% | 46.8% | 90.2% | 4300*1300*2000 | 4400 | |||
EM-250N5 | 250 | E2848LE322 | 265 | LSA Series | V8 | 36.8% | 48.7% | 85.5% | 4300*1300*2000 | 4600 | |||
EM-270N5 | 270 | E3262E302 | 275 | LSA Series | V12 | 39.6% | 54% | 93.6% | 4300*1300*2000 | 4600 | |||
EM-350N5 | 350 | E3268LE212 | 370 | LSA Series | V8 | 41.9% | 52.5% | 94.4% | 5200*1600*2100 | 5700 | |||
EM-400N5 | 400 | E2842LE322 | 420 | LSA Series | V12 | 38.6% | 44.4% | 83% | 5200*2000*2100 | 6400 | |||
EM-450N5 | 450 | E3262E302 | 500 | LSA Series | V12 | 42.1% | 49.3% | 91.4% | 5300*2000*2100 | 6900 | |||
EM-520N5 | 520 | E3262LE202 | 550 | LSA Series | V12 | 38.8% | 48.3% | 87.1% | 5500*2000*2100 | 7500 | |||
·EP-875N5 | 875 | 4016-61TRS1 | 912 | LSA Series | V16 | 38.2% | 44.8% | 83% | 7000*2000*2200 | 13500 | |||
·EP-1000N5 | 1000 | 4016-61TRS2 | 1042 | LSA Series | V16 | 38.7% | 42.2% | 80.9% | 7000*2000*2200 | 18000 |
MAN Coal Mine Gas Generator Set (60Hz, 1800rpm) |
|||||||||||||
Model
|
COP
|
Engine Model
|
Engine
Power |
Alternator
|
Configura
tion |
Elec. Eff.
|
Heat Eff.
|
Tot. Eff.
|
Overall
dimension (L*W*H)(mm) |
Weight
(kg) |
Click for
Detail Data |
||
KW
|
MAN
|
KW
|
Leroy Somer
or Equal |
||||||||||
EM-60N6
|
60 | E0834E302 |
62
|
LSA Series
|
L4 | 35.3% | 53.5% | 88.8% |
2800*1050*1550
|
1900
|
|||
EM-66N6
|
66 | E0834LE302 | 68 |
LSA Series
|
L4 | 37.6% | 51.9% | 89.5% |
2800*1050*1550
|
1900
|
|||
EM-85N6
|
85 | E0836LE302 | 85 |
LSA Series
|
L6 | 37% | 53.6% | 90.6% |
3550*1100*1650
|
2100 | |||
EM-100N6 | 100 | E0836LE202 | 110 |
LSA Series
|
L6 | 33.7% | 50.8% | 84.5% | 3700*1150*1750 | 2200 | |||
EM-150N6 | 150 | E2876E302 | 170 |
LSA Series
|
L6 | 38% | 54.1% | 92.1% | 4000*1225*1875 | 3300 | |||
EM-200N6 | 200 | E2876LE302 | 210 | LSA Series | L6 | 35.3% | 50.8% | 86.1% | 4300*1300*2000 | 4400 | |||
EM-250N6 | 250 | E2676LE202 | 250 | LSA Series | L6 | 39.4% | 49.1% | 88.5% | 4300*1300*2000 | 4600 | |||
EM-280N6 | 280 | E2848LE322 | 295 | LSA Series | V8 | 36.1% | 49.5% | 85.6% | 4300*1300*2000 | 4600 | |||
EM-300N6 | 300 | E3262E302 | 300 | LSA Series | V12 | 38.7% | 54.9% | 93.6% | 4500*1400*2000 | 4960 | |||
EM-390N6 | 390 | E3268LE212 | 390 | LSA Series | V8 | 40.2% | 47.7% | 87.7% | 5200*2000*2100 | 6400 | |||
EM-420N6 | 420 | E3262LE232 | 450 | LSA Series | V12 | 38.4% | 52.3% | 90.7% | 5400*2000*2100 | 6500 | |||
EM-560N6 | 560 | E3262LE202 | 580 | LSA Series | V12 | 38.2% | 49.9% | 88.1% | 5500*2000*2100 | 7500 | |||
·EP-960N6 | 960 | 4016-61TRS1 | 980 | LSA Series | V16 | 38.2% | 44.8% | 83% | 7000*2000*2200 | 13500 | |||
·EP-1100N6 | 1100 | 4016-61TRS2 | 1210 | LSA Series | V16 | 38.7% | 42.2% | 80.9% | 7000*2200*2400 | 18000 |
• Above Gensets Models are based on 50HZ/1500RPM and 60HZ/1800RPM.
• Above Gensets Models are based on AC Voltage of 400/230V and 480V/240V, Other special low AC Voltage and High Voltage of 6.3KV-13.8KV are available for your options.
• Engine Model with “·” means driven by Perkins engines.
• Above data is based on gas heat value 36MJ/ Nm³; Power Factor Cosφ=1; Exhaust Temperature decreased to 120℃; Heat Value Tolerance 8%, Output Power Tolerance 5%.
• NOX Emissions Level <500mg/m3 . Special requirements for emissions data such as EPA Standard can be realized by adding SCR and CO Catalyst.
• Engine Overhaul Time is around 50000~60000 hours.
• MAN Engines warranty terms: 15 Months after delivery , 12 Months after Installment or 8000 hours accumulated running time, which is subject to the earlier one.
• The data herein can vary depending on individual production requirements or due to improved technology.
MWW Coalmine Gas Engines & Generators & CCHP (from 400KW upto 4500KW)
MWWCoalmine Methane Gas Engines made in Germany (50Hz) |
|||||||||||||
Model
|
COP
(KW)
|
Engine
Model |
Bore*Stroke
(mm) |
Displace
ment (L) |
Ratation
Speed (rpm) |
Elec.
Eff. (%) |
Therm.
Eff. (%) |
Total
Eff. (%) |
Overall
dimension (L*W*H)(mm) |
Weight
(kg) |
Click for
Detail Data |
||
EMW-400N5
|
400 |
TCG2016V08C /
CG132-8 |
132*160 |
17.5
|
1500 | 42.3 |
45.2
|
87.5 |
3090*1490*2190
|
5340
|
|
||
EMW-600N5 | 600 | TCG2016V12C / CG132-12 |
132*160 |
26.3
|
1500 | 42.0 | 45.8 | 87.8 |
3690*1490*2190
|
7000
|
|||
EMW-800N5 | 800 |
TCG2016V16C /
CG132-16 |
132*160 |
35
|
1500 | 42.5 | 45.3 | 87.8 |
4090*1590*2190
|
8450
|
|||
EMW-1000N5
|
1000 |
•TCG2020V12K1 /
CG170-12 |
170*195
|
53.1
|
1500 | 40.0 | 47.0 | 87.0 |
4660*1810*2210
|
11200
|
|||
EMW-1125N5 | 1125 |
•TCG2020V12K /
CG170-12 |
170*195
|
53.1
|
1500 | 40.9 | 45.6 | 86.5 | 4790*1810*2210 | 11700 | |||
EMW-1200N5 | 1200 |
♦TCG2020V12 /
CG170-12 |
170*195
|
53.1
|
1500 | 43.6 | 43.3 | 86.9 | 4790*1810*2210 | 11700 | |||
EMW-1500N5 | 1500 |
•TCG2020V16K /
CG170-16 |
170*195
|
70.8
|
1500 | 40.9 | 45.7 | 86.6 | 5430*1810*2210 | 13320 | |||
EMW-1560N5 | 1560 |
♦TCG2020V16 /
CG170-16 |
170*195
|
70.8
|
1500 | 43.2 | 43.8 | 87.0 | 5430*1810*2210 | 13320 | |||
EMW-2000N5 | 2000 |
♦TCG2020V20 /
CG170-20 |
170*195
|
88.5 | 1500 | 43.7 | 43.2 | 86.9 | 6200*1710*2190 | 17900 | |||
EMW-3333N5 | 3333 |
TCG2032V12 /
CG260-12 |
260*320 |
203.9
|
1000 | 43.9 | 42.6 | 86.5 | 7860*2660*3390 | 43100 | |||
EMW-4500N5 | 4500 |
TCG2032BV16 /
CG260-16 |
260*320 | 271.8 | 1000 | 44.6 | 42.2 | 86.8 | 9200*2690*3390 | 51200 |
MWWCoalmine Methane Gas Engines made in Germany (60Hz) |
|||||||||||||
Model
|
COP
(KW)
|
Engine
Model |
Bore*Stroke
(mm) |
Displace
ment (L) |
Ratation
Speed (rpm) |
Elec.
Eff. (%) |
Therm. E
ff. (%) |
Total
Eff. (%) |
Overall
dimension (L*W*H)(mm) |
Weight
(kg) |
Click for
Detail Data |
||
EMW-400N6
|
400 |
TCG2016V08C /
CG132-8 |
132*160 |
17.5
|
1800 | 41.4 |
46.0
|
87.4 |
3170*1490*2190
|
5120
|
|
||
EMW-600N6 | 600 | TCG2016V12C / CG132-12 |
132*160 |
26.3
|
1800 | 41.3 | 46.5 | 87.8 |
3770*1490*2190
|
6260
|
|||
EMW-800N6 | 800 |
TCG2016V16C /
CG132-16 |
132*160 |
35
|
1800 | 41.6 | 46.3 | 87.9 |
4130*1490*2190
|
6780
|
|||
EMW-1125N6 | 1125 |
•TCG2020V12K /
CG170-12 |
170*195
|
53.1
|
1500 | 40.7 | 45.6 | 86.3 | 5970*1790*2210 | 12850 | |||
EMW-1200N6 | 1200 |
♦TCG2020V12 /
CG170-12 |
170*195
|
53.1
|
1500 | 43.4 | 43.2 | 86.6 | 5970*1790*2210 | 12850 | |||
EMW-1500N6 | 1500 |
•TCG2020V16K /
CG170-16 |
170*195
|
70.8
|
1500 | 40.6 | 45.7 | 86.3 | 6640*1790*2210 | 14850 | |||
EMW-1560N6 | 1560 |
♦TCG2020V16 /
CG170-16 |
170*195
|
70.8
|
1500 | 43.0 | 43.7 | 86.7 | 6640*1790*2210 | 14850 | |||
EMW-2000N6 | 2000 |
♦TCG2020V20 /
CG170-20 |
170*195
|
88.5 | 1500 | 43.4 | 43.2 | 86.6 | 7470*1710*2190 | 19400 | |||
EMW-3000N6 | 3000 |
TCG2032V12 /
CG260-12 |
260*320 |
203.9
|
900 | 43.9 | 42.1 | 86.0 | 8000*2660*3390 | 40650 | |||
EMW-4000N6 | 4000 |
TCG2032V16 /
CG260-16 |
260*320 | 271.8 | 900 | 43.8 | 42.2 | 86.0 | 9420*2690*3390 | 53300 |
• Above engine marked "•" version optimized for island operation and load compensation.
• Above engine marked "♦" means optimized efficiency version.
• Transport dimensions for gensets; components set up separately must be taken into consideration.
• According to ISO 3046/1 at U=0.4 kV,cos=1.0 for 50 Hz and methane number of MN-70 (MN-80 for some engine models) for natural gas.
• Exhaust gas cooled to 120°C for natural gas and 150°C (TCG2032 180°C) for biogas.
• NO ≤ 500 mg/Nm³; exhaust gas dry at 5 % O2.
• Data for special gas and dual gas operation on request.